Force Monitoring Not Working
For force settings not configured:
- The Closing/Opening Force is probably not set or not set properly.
- By default the PULSE 300 ships with Closing and Opening Force set to OFF.
- Enter the STARTUP MENU to adjust the 2 forces where a value of 1 is the most sensitive and 99 is the least sensitive.
- After setting the Opening/Closing Force, the operator will prompt you to calibrate the door by opening and closing; just follow the instructions on the LCD screen.
- You can also refer to the Calibration section in the installation manual .